<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-31 04-52-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 59 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.3 kHz 69 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19078 0,8596
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,8 dBr 3,47 dBr 5,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 4:52, 31.10.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,8596 Acquired: 2025/10/31 4.51.48 Total samples: 19078 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,0 dBr MIN: 1,8 dBr AVE: 3,47 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2025/10/31 4.51.47) 04.38 04.40 04.42 04.44 04.46 04.48 04.50 0 2 4 6 Pm [dBr]